A Modelbased Framework for Optimal Systems Integration of Adsorption Chillers

A Modelbased Framework for Optimal Systems Integration of Adsorption Chillers

The global demand for cooling increases and poses a challenge for the stability of electrical grids and the emission targets. Thermally-driven adsorption chillers can meet this challenge by substituting electricity with thermal energy. However, although adsorption chillers are primarily driven by thermal energy, practical exp......
fra 681,63
Tilgjengelig i 1 butikker
Forhåndsbestill
Frakt og levering
Beskrivelse
The global demand for cooling increases and poses a challenge for the stability of electrical grids and the emission targets. Thermally-driven adsorption chillers can meet this challenge by substituting electricity with thermal energy. However, although adsorption chillers are primarily driven by thermal energy, practical experience shows that the electricity savings often hardly compensate the electricity demand of the auxiliaries, such as pumps and fans. Thus, smart systems integration is crucial. Systems integration of adsorption chillers is challenging due to several features: (1) intrinsic dynamics; (2) close interaction between various system components; and (3) strong coupling of design, control, and operating conditions. These features lead to a variety of degrees of freedom, which make it difficult to use simple design and control rules for systems integration.To move towards optimal systems integration of adsorption chillers, this thesis provides appropriate models and methods. First of all, a model of an adsorption chiller is developed, which is accurate enough to consider quantities needed on system level, but also computationally sufficiently efficient for model-based optimizations. To demonstrate the model accuracy, the model is calibrated and validated for two types of adsorption chillers, a lab-scale one-bed adsorption chiller and a commercial two-bed adsorption chiller.Subsequently, the presented model is used for two areas of systems integration: the integration in hybrid systems and the integration within the auxiliaries. To exemplify the integration in a hybrid system, an adsorption chiller is integrated into a CO2 vapor compression cycle to efficiently provide refrigeration with natural refrigerants only. The exemplified integration identifies a significant potential for energy savings, which can be fully exploited by optimal design and control of the hybrid system. The demonstrated integration in hybrid systems is also an example for a conceptual integration, which quantifies the potential of a specific application.To integrate the adsorption chiller within the auxiliaries, an optimization-based method is presented for detailed sizing and control of all system components including auxiliaries. The presented method is demonstrated for a solar-thermally-driven adsorption chiller system and determines both, an energetically and an economically optimal design and control. In summary, the thesis provides a comprehensive framework for optimal systems integration of adsorption chillers: from model validation over conceptual integration to detailed design and control.

Produktinformasjon

A Modelbased Framework for Optimal Systems Integration of Adsorption Chillers

Økningen i global etterspørsel etter kjøling setter stor press på elektriske nettverk og klimagassmål. Med termisk-drevne adsorpsjonskjølere kan vi møte denne utfordringen ved å erstatte elektrisitet med termisk energi. Men hvordan kan vi sikre at vi maksimerer energieffektiviteten? Her kommer vårt innovative rammeverk inn i bildet!

Optimal systemintegrering med adsorpsjonskjølere

Vår tilnærming, A Modelbased Framework, gir en robust løsning for optimal integrering av adsorpsjonskjølere i komplekse systemer. Her er noen nøkkelfunksjoner:

  • Modellutvikling: Vi utvikler en modell av adsorpsjonskjøleren, som er nøyaktig nok til å vurdere nødvendige mengder på systemnivå, samtidig som den er effektiv for modellbaserte optimaliseringer.
  • Praktisk validering: Modellen er validert på to typer adsorpsjonskjølere; en laboratorium-modell og en kommersiell to-sengs kjøler, noe som sikrer pålitelighet.
  • Integrering i hybrid systemer: Vi demonstrerer hvordan vår modell kan integreres i CO2 dampkompresjonssystemer for å levere kjøling med kun naturlige kjølemidler.
  • Optimalisering av komponenter: Gjennom et optimeringsbasert metodologi gir vi detaljert sizing og kontroll av alle systemkomponenter, inkludert auxilary-enheter som pumper og vifter.

Hvorfor velge vårt rammeverk?

Den unike synergi av design, kontroll, og driftsbetingelser gir deg friheten til å utforme ditt kjølesystem på en måte som maksimerer energieffektivitet og reduserer kostnader:

  • Energi: Reduser strømforbruket og oppnå betydelige energibesparelser i driften.
  • Kostnadseffektivitet: Optimal design gir ikke bare energibesparelser, men også økonomisk gevinst.

Oppdag mulighetene med A Modelbased Framework for Optimal Systems Integration of Adsorption Chillers, og vær i forkant av kjølebehovene i fremtiden!

Spesifikasjon

Produkt
ProduktnavnA Modelbased Framework for Optimal Systems Integration of Adsorption Chillers
MerkeOther Brand

Pris og prishistorikk

Akkurat nå er 681,63 den billigste prisen for A Modelbased Framework for Optimal Systems Integration of Adsorption Chillers blant 1 butikker hos Prisradar. Sjekk også vår topp 5-rangering av beste teknikk, ingeniør og primær for å være sikker på at du gjør det beste kjøpet.

Prisutvikling:
Vokser
Laveste pris:
623,2
Gjennomsnittspris:
675,-
Høyeste pris:
681,63
Beste tilbudet:
platekompaniet.no
Ikke tilgjengelig